Product Characteristics
....01.
Can be converted to 5Gas Analyzer Module.
....02.
Automatic Temperature Adjustment (2~8 min)
....03.
Slick Design
....04.
Automatic Preheat Time Adjustment (2~8 min) ......
...
Product Specifications
...QRO-401(
Inspection Facility Purpose
)
|
| Target Subject |
CO, HC, CO2, O2, ¥ë (Excess Air Ratio), AFR, NOx (optional) |
| Sensor Theory |
CO, HC, CO2: Non-Dispersive Infrared Analysis (NDIR)
O2, NOx: Electrochemical Cell |
| Analysis Range |
CO
|
0.00
~ 9.99% |
HC
|
0
~ 9999 ppm |
Resolving Power
|
0.01%
|
1
ppm |
| Display |
4
digit 7segment LED |
4
digit 7segment LED |
| Analysis Range |
CO2
|
0.0
~ 20.0% |
O2
|
0.00
~ 25.00 % |
Resolving Power
|
0.1%
|
0.01
% |
| Display |
4
digit 7segment LED |
4
digit 7segment LED |
Analysis Range
|
¥ë
|
0
~ 2.000 |
AFR
|
0.0
~ 99.0 |
Resolving Power
|
0.001
|
0.1
|
| Display |
4
digit 7segment LED |
4
digit 7segment LED |
Repetition Rate
|
Lower than ¡¾2% FS |
Response Time
|
Within 10 seconds (90% of the time)
|
Preheat Time
|
Approx. 2~8 minutes |
Sample Requirement
|
4
~ 6 L/min |
Voltage Use
|
AC110V
or AC220V ¡¾10%, 50/60Hz |
Power Consumption
|
Approx. 50W |
Category Temperature
|
0¡É
~ 40¡É |
Size
|
285
(W) * 410 (D) * 155 (H) mm |
Weight
|
Approx. 4.5kg |
| Included Accessories |
Probe, Probe Hose, Emergency Fuse, Water Leak Testing Cap, Emergency Filter, Instruction Manual, Power Cord, Ground Wire, and Type Approval Certificate
|
Optional Accessories
|
Printer, Printer Paper, RS232
|
|
|
|
|
|
|
|