Product Characteristics

....01. Can be converted to 5Gas Analyzer Module.
....02. Automatic Temperature Adjustment (2~8 min)
....03. Slick Design
....04. Automatic Preheat Time Adjustment (2~8 min) ...
....* Registered as Conditional Auto Repair Equipment

Product Specifications

...QRO-401

Target Subject CO, HC, CO2, O2, ¥ë (Excess Air Ratio), AFR, NOx (optional)
Sensor Theory CO, HC, CO2: Non-Dispersive Infrared Analysis (NDIR)
O2, NOx: Electrochemical Cell
Analysis Range CO 0.00 ~ 9.99% HC 0 ~ 9999 ppm
Resolving Power
0.01% 1 ppm
Display 4 digit 7segment LED 4 digit 7segment LED
Analysis Range CO2 0.0 ~ 20.0% O2 0.00 ~ 25.00 %
Resolving Power
0.1% 0.01 %
Display 4 digit 7segment LED 4 digit 7segment LED
Analysis Range
¥ë 0 ~ 2.000 AFR 0.0 ~ 99.0
Resolving Power
0.001 0.1
Display 4 digit 7segment LED 4 digit 7segment LED
Repetition Rate
Lower than ¡¾2% FS
Response Time
Within 10 seconds (90% of the time)
Preheat Time
Approx. 2~8 minutes
Sample Requirement
4 ~ 6 L/min
Voltage Use
AC110V or AC220V ¡¾10%, 50/60Hz
Power Consumption
Approx. 50W
Category Temperature
0¡É ~ 40¡É
Size
285 (W) * 410 (D) * 155 (H) mm
Weight
¾à 4.5 kg
Included Accessories
Probe, Probe Hose, Emergency Fuse, Water Leak Testing Cap, Emergency Filter, Instruction Manual, Power Cord, Ground Wire, and Type Approval Certificate

Optional Accessories

Printer, Printer Paper, RS232